Need advice on the right pump for your application? Call the team on 01773 533 283.

Talk to us today: +44 (0) 1773 533 283

My Enquiry List: 0 itemsView list

     
  • Fast track icon

    MODELS AVAILABLE FROM STOCK Shorter lead times. Your deadlines met.

  • lightbulb icon

    APPLICATION EXPERIENCE YOU CAN RELY ON We'll specify the ideal solution for your process.

  • Piggy Bank Image Icon

    LOWER TOTAL LIFETIME COST SOLUTIONS Efficient, easy to maintain & long life design.

Refine your results by:

Update Results

Pump Type

Application

Manufacturer

Max. Flow Rate

Pressure

Max Temperature

Max Viscosity

Solids Size

Drive

Priming

Orientation

Material

Update Results

Condensate Pumps Page 2

Condensate extraction pumps for boilers, furnaces & HVAC systems

A condensate pump is designed to pump condensate water produced by conditioned building air that has been cooled or heated, including refrigerated or freezer air, boiler steam in heat exchangers and radiators and furnace exhaust streams. As its names suggests, a condensate removal pump is used to extract condensate from the HVAC system’s pipework and move it around the plant where it can be treated, converted back to steam and then pumped back into the system to be reused.

Air conditioning condensate pumps usually only have to handle relatively clean water condensation, whereas steam condensate from boilers and furnaces often includes contaminants including dust, or chemicals from an exhaust system. Therefore boiler and furnace condensate pumps need to be able to cope with more demanding conditions. Side channel pumps are usually the best options for condensate water pumps thanks to their ability to handle liquids with gas and air content.

View more information about Condensate Pumps

A condensate pump is designed to pump condensate water produced by conditioned building air that has been cooled or heated, including refrigerated or freezer air, boiler steam in heat exchangers and radiators and furnace exhaust streams. As its names suggests, a condensate removal pump is used to extract condensate from the HVAC system’s pipework and move it around the plant where it can be treated, converted back to steam and then pumped back into the system to be reused.

Air conditioning condensate pumps usually only have to handle relatively clean water condensation, whereas steam condensate from boilers and furnaces often includes contaminants including dust, or chemicals from an exhaust system. Therefore boiler and furnace condensate pumps need to be able to cope with more demanding conditions. Side channel pumps are usually the best options for condensate water pumps thanks to their ability to handle liquids with gas and air content.

Refine your results by:

Update Results

Pump Type

Application

Manufacturer

Max. Flow Rate

Pressure

Max Temperature

Max Viscosity

Solids Size

Drive

Priming

Orientation

Material

Update Results

22 Results

Sort by:

Sero SEMIS Self Priming Side Channel Pump

Sero SEMIS Self Priming Side Channel Pump

  • Up to 7.5M³H
  • Max. Head 200M
  • Max. Temp 100°C
Liverani GR ADPE Explosion Proof Side Channel Pump

Liverani GR ADPE Explosion Proof Side Channel Pump

  • Up to 30 M³H
  • Max. Head 40M
  • Max. Temp 165°C
  • ¾” - 2½” Outlet
  • Max. Viscosity 100 cP
Liverani INV Side Channel Pump

Liverani INV Side Channel Pump

  • Up to 58.7 M³H
  • Max. Head 60M
  • Max. Temp 165°C
  • ¾” - 3” Outlet
  • Max. Viscosity 100 cP
Liverani SEP Side Channel Pump

Liverani SEP Side Channel Pump

  • Up to 54 M³H
  • Max. Head 55M
  • Max. Temp 165°C
  • ¾” - 3” Outlet
  • Max. Viscosity 100 cP
Liverani Special Side Channel Pump

Liverani Special Side Channel Pump

  • Up to 13.8 M³H
  • Max. Head 30M
  • Max. Temp 100°C
  • ¾” up to 2” Outlet
  • Max. Viscosity 100 cP
Liverani Special FM Side Channel Pump

Liverani Special FM Side Channel Pump

  • Up to 54 M³H
  • Max. Head 55M
  • Max. Temp 100°C
  • 1¼” - 3” Outlet
  • Max. Viscosity 100 cP
Azcue TK Horizontal Multistage Centrifugal Pump

Azcue TK Horizontal Multistage Centrifugal Pump

  • Up to 800M³H
  • Max. Head 400M
  • Max. Temp 120°C
  • DN25 - 300 Outlet
Azcue VTK Vertical Multistage Centrifugal Pump

Azcue VTK Vertical Multistage Centrifugal Pump

  • Up to 300M³H
  • Max. Head 400M
  • Max. Temp 120°C
  • DN25 - 150 Outlet
Azcue TKR Horizontal Multistage Centrifugal Pump

Azcue TKR Horizontal Multistage Centrifugal Pump

  • Up to 500M³H
  • Max. Head 600M
  • Max. Temp 140°C
  • DN32 - 150 Outlet
Azcue TKK Horizontal Multistage Centrifugal Pump

Azcue TKK Horizontal Multistage Centrifugal Pump

  • Up to 900M³H
  • Max. Head 900M
  • Max. Temp 160°C
  • DN40 - 250 Outlet

22 Results

 

If you are unable to find the product that you are looking for then please contact us via sales@castlepumps.com or +44 (0) 1773 533 283

 

Castle Pumps are fully accredited to enable you to buy with confidence. Our accreditation includes: Our accreditation A division of the CTS Group, Part of Flow Max Ltd.